Clinical Practices in Central Venous Catheter Mechanical Adverse Events
Enyo A Ablordeppey1, Wendy Huang1, Ian Holley1
1Department of Anesthesiology, Washington University School of Medicine, St. Louis, MO, USA.
Abstract:
Background: Over 5 million central venous catheters (CVCs) are placed annually. Pneumothorax and catheter malpositioning are common adverse events (AE) that requires attention. This study aims to evaluate local practices of mechanical complication frequency, type, and subsequent intervention(s) related to mechanical AE with an emphasis on catheter malpositioning. Methods: This is a retrospective review of CVC placements in a tertiary hospital setting from 1/2013 to 12/2013. Pneumothorax and CVC positioning were evaluated on post-insertion chest x-ray (CXR). Malposition was defined as unintended placement of the catheter in a vessel other than the intended superior vena cava on CXR. Catheter reposition was defined as radiographic evidence of a new catheter with removal of the old catheter less than 24hrs after initial placement. Data points analyzed included pneumothorax and thoracostomy rate, CVC malposition frequency, catheter reposition rate, catheter duration, and incidence of complications such as catheter associated venous thrombosis. Result: Among 2045 eligible CVC insertions, pneumothoraces occurred in 14 (0.7%; 95%CI 0.38, 1.17) and malpositions were identified in 275 (13.4%; 95% CI 12.3, 15.3). The proportion of pneumothoraces that required tube thoracostomy was 57%. The proportion of CVCs with malposition that were removed or replaced within 24h was 32.7%. "Malpositioned" catheters that were left in place by the clinical team (n = 185) had an average catheter duration of 8.2 days (95% CI 7.2, 9.3) versus 7.2 days (95% CI 6.17, 8.23) for catheters that were replaced after initial malposition (p = 0.14, t test). The incidence of venous thrombosis in repositioned "malpositioned" catheters was 7.8% versus 4.9% for "malpositioned" catheters that were left in place. Conclusions: Clinically significant catheter malposition and pneumothorax after CVC insertion are low. In this study, replaced and non-replaced "malpositioned" catheters had similar catheter duration and rates of complications, challenging the current dogma of CVC malposition practice.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Venous Thrombosis III: Interprofessional Care
Cardiac Catheterization IV: Nursing Management
Venous Thrombosis IV: Nursing Management
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...