Related Experiment Video
Updated: Sep 7, 2025

Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
Validation of an instrument for the evaluation of exchange transfusion (INEXTUS) via an OSCE
María José Maldonado Calderón1, Sergio Iván Agudelo Pérez2, Natalia Becerra2
1Universidad de La Sabana and Clínica Universidad de La Sabana, Chía, Colombia. maria.maldonado5@unisabana.edu.co.
Introduction:
Exchange transfusion is the treatment of choice for patients with severe hyperbilirubinemia who do not respond to phototherapy. This procedure is highly complex and requires substantial expertise to perform, however it´s not done frequently enough to guarantee adequate training. Traditional learning scenarios do not have a space reserved for teaching this procedure or an instrument that fully and objectively evaluates the skills that a professional must acquire. OBJECTIVES: The purpose was to construct and evaluate the INEXTUS instrument´s validity evidence relevant to internal structure, in a simulated scenario through the performance of an objective structured clinical exam (OSCE). MATERIALS AND METHODS: The Delphi consensus methodology was utilized to design the instrument; six experts participated through three rounds using the Google Forms platform. The categories and items previously obtained were subjected to validation by nine experts through a dichotomous survey. Prior to data collection, the evaluators were trained through a pilot test with 10 medical students. Subsequently, all residents of a paediatric programme were evaluated through the OSCE methodology in a simulated scenario, with 6 stations, of a clinical case of a new-born with an explicit need for exchange transfusion. During their participation in the scenario, the residents were first evaluated with the instrument developed. Additionally, audio and video filming of all students who participated was performed with the aim of conducting a second evaluation two weeks after the first four evaluators participated.
Results:
The final INEXTUS instrument consists of 46 subitems grouped into 23 items divided into 6 categories, demonstrating an inter-rater intraclass correlation coefficient of 0.96 (95% CI 0.94, 0.98 p-value < 0.001). For the Fleiss Kappa of the 23 items evaluated, concordance was evaluated for 14 items but could not be determined for the 9 remaining items because all the ratings were equal, either because the items were not performed or they were all performed adequately. Of the 14 items, 9 good scores were obtained (95% CI 0.61 to 0.8; p value < 0.001), and 5 very good scores were obtained (95% CI 0.81 to 1; p value < 0.001).
Conclusions:
The INEXTUS instrument evaluates exchange transfusion skills in medical personnel in training in simulated scenarios using the OSCE methodology; it has high validity and reliability and is a high-impact educational tool.
More Related Videos
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
10:15The Use of the Ex Vivo Chandler Loop Apparatus to Assess the Biocompatibility of Modified Polymeric Blood Conduits
Published on: August 20, 2014
Related Concept Videos
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...