Related Experiment Video
Updated: Sep 7, 2025

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
Published on: June 5, 2017
Novel, User-Friendly Experimental and Analysis Strategies for Fast Voltammetry: Next Generation FSCAV with Artificial
Sergio Mena1, Marco Visentin1, Colby E Witt2
1Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom.
Abstract:
Fast-scan adsorption-controlled voltammetry (FSCAV) was recently derived from fast-scan cyclic voltammetry to estimate the absolute concentrations of neurotransmitters by using the innate adsorption properties of carbon fiber microelectrodes. This technique has improved our knowledge of serotonin dynamics in vivo. However, the analysis of FSCAV data is laborious and technically challenging. First, each electrode requires post-experimental in vitro calibration. Second, current analysis methods are semi-manual and time-consuming and require a steep learning curve. Finally, the calibration methods used do not adapt to nonlinear electrode responses. In this work, we provide freely accessible computational solutions to these issues. First, we design an artificial neural network (ANN) and train it with a large data set (calibrations from 140 electrodes by six different researchers) to achieve calibration-free estimations and improve predictive error. We discuss the power of the ANN to obtain a low predictive error without electrode-specific calibrations as a function of being able to predict the sensitivity of the electrode. We use the ANN to successfully predict the absolute serotonin concentrations of real in vivo data. Finally, we create a fast and user-friendly, fully automated analysis web platform to simplify and reduce the expertise required for the postanalysis of FSCAV signals.
More Related Videos
06:40Combined Infusion and Stimulation with Fast-Scan Cyclic Voltammetry CIS-FSCV to Assess Ventral Tegmental Area Receptor Regulation of Phasic Dopamine
Published on: April 23, 2020
10:23Measuring In Vivo Changes in Extracellular Neurotransmitters During Naturally Rewarding Behaviors in Female Syrian Hamsters
Published on: September 12, 2017
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Factors Affecting Measurements