Related Experiment Video
Updated: Sep 7, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Improving cone-beam CT quality using a cycle-residual connection with a dilated convolution-consistent generative
Liwei Deng1, Mingxing Zhang1, Jing Wang2
1Heilongjiang Provincial Key Laboratory of Complex Intelligent System and Integration, School of Automation, Harbin University of Science and Technology, Harbin, Heilongjiang, People's Republic of China.
Abstract:
Objective.Cone-Beam CT (CBCT) often results in severe image artifacts and inaccurate HU values, meaning poor quality CBCT images cannot be directly applied to dose calculation in radiotherapy. To overcome this, we propose a cycle-residual connection with a dilated convolution-consistent generative adversarial network (Cycle-RCDC-GAN).Approach.The cycle-consistent generative adversarial network (Cycle-GAN) was modified using a dilated convolution with different expansion rates to extract richer semantic features from input images. Thirty pelvic patients were used to investigate the effect of synthetic CT (sCT) from CBCT, and 55 head and neck patients were used to explore the generalizability of the model. Three generalizability experiments were performed and compared: the pelvis trained model was applied to the head and neck; the head and neck trained model was applied to the pelvis, and the two datasets were trained together.Main results.The mean absolute error (MAE), the root mean square error (RMSE), peak signal to noise ratio (PSNR), the structural similarity index (SSIM), and spatial nonuniformity (SNU) assessed the quality of the sCT generated from CBCT. Compared with CBCT images, the MAE improved from 28.81 to 18.48, RMSE from 85.66 to 69.50, SNU from 0.34 to 0.30, and PSNR from 31.61 to 33.07, while SSIM improved from 0.981 to 0.989. The sCT objective indicators of Cycle-RCDC-GAN were better than Cycle-GAN's. The objective metrics for generalizability were also better than Cycle-GAN's.Significance.Cycle-RCDC-GAN enhances CBCT image quality and has better generalizability than Cycle-GAN, which further promotes the application of CBCT in radiotherapy.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Improving Translational Accuracy

