Low-dose CT hounsfield units: a reliable methodology for assessing vertebral bone density in radiographic axial
Mary Lucy Marques1,2, Nuno Pereira da Silva3, Desirée van der Heijde4
1Department of Rheumatology, Leiden University Medical Center, Leiden, The Netherlands mary.lucy.marques@gmail.com.
Objective:
Studying vertebral bone loss in radiographic axial spondyloarthritis (r-axSpA) has been challenging due to ectopic bone formation. We cross-sectionally analysed low-dose CT (ldCT) trabecular bone density Hounsfield units (HU) measurements and calculated inter-reader reliability at the vertebral level in patients with r-axSpA.
Methods:
LdCT scans of 50 patients with r-axSpA from the sensitive imaging in ankylosing spondylitis study, a multicentre 2-year prospective cohort were included. Trabecular bone HU taken from a region of interest at the centre of each vertebra (C3-L5) were independently assessed by two trained readers. HU mean (SD), and range were provided at the vertebral level, for each reader and centre separately. Inter-reader reliability and agreement were assessed using intraclass correlation coefficients (ICC; single measurements, absolute agreement, two-way mixed effects models); smallest detectable difference and Bland-Altman plots.
Results:
Overall, 1100 vertebrae were assessed by each reader. HU values decreased from cranial to caudal vertebrae. For readers 1 and 2 respectively, the highest mean (SD) HU value was obtained at C3 (354(106) and 355(108)), and the lowest at L3 (153(65) and 150 (65)). Inter-reader reliability was excellent (ICC(2,1):0.89 to 1.00). SDD varied from 4 to 8. For most vertebrae, reader 1 scored somewhat higher than reader 2 (mean difference of scores ranging from -0.6 to 2.9 HU). Bland-Altman plots showed homoscedasticity.
Conclusion:
LdCT measurement of HU is a feasible method to assess vertebral bone density in r-axSpA with excellent inter-reader reliability from C3 to L5. These results warrant further validation and longitudinal assessment of reliability.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT