Diagnostic usefulness of cone-beam computed tomography versus multi-detector computed tomography for sinonasal
Miran Han1,2, Hyun Jun Kim3, Jin Wook Choi1
1Department of Radiology Ajou University Hospital, Ajou University School of Medicine Suwon Republic of Korea.
Objective:
Cone-beam computed tomography (CBCT) is a promising imaging modality for sinonasal evaluation, with advantages of relatively low radiation dose, low cost, and quick outpatient imaging. Our study aimed to compare the diagnostic performance and image quality of CBCT with those of multi-detector computed tomography (MDCT) with different slice thickness.
Methods:
We retrospectively reviewed 60 consecutive patients who had undergone both CBCT and MDCT. MDCT images was reconstructed with 1 and 3 mm slice thickness. The quantitative image quality parameters (image noise, signal-to-noise ratio [SNR], and contrast-to noise ratio [CNR] were calculated and compared between the two imaging modalities. Two observers (ENT surgeon and neuroradiologist) evaluated the presence of seven sinonasal anatomic variations in each patient and interobserver agreements were analyzed. The diagnostic performance of CBCT (0.3 mm) and MDCT (3 mm) was assessed and compared with that of high resolution MDCT (1 mm), which is considered as the gold standard.
Results:
The image noise was significantly higher and SNR and CNR values were lower in the CBCT (0.3 mm) group than in the MDCT groups (1 and 3 mm). The diagnostic performance of CBCT (0.3 mm) was similar to that of MDCT (1 mm) and superior to that of MDCT (3 mm). The highest interobserver agreement was for high resolution MDCT (1 mm), followed by CBCT (0.3 mm), and MDCT (3 mm).
Conclusion:
Considering its low radiation dose, low cost, and ease of clinical access, CBCT may be a useful imaging modality for as first line sinonasal evaluation and repeated follow up.Study design: Retrospective study in a tertiary referral university center.Level of evidence: NA.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
07:00Identification of OTX1 and OTX2 As Two Possible Molecular Markers for Sinonasal Carcinomas and Olfactory Neuroblastomas
Published on: February 28, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT