Related Experiment Video
Updated: Jul 15, 2026

A Murine Model of Dengue Virus-induced Acute Viral Encephalitis-like Disease
Published on: April 28, 2019
The Omicron variant BA.1.1 presents a lower pathogenicity than B.1 D614G and Delta variants in a feline model of
Mathias Martins1, Gabriela M do Nascimento1, Mohammed Nooruzzaman1
1Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, United States of America.
Abstract:
Omicron (B.1.1.529) is the most recent SARS-CoV-2 variant of concern (VOC), which emerged in late 2021 and rapidly achieved global predominance in early 2022. In this study, we compared the infection dynamics, tissue tropism and pathogenesis and pathogenicity of SARS-CoV-2 D614G (B.1), Delta (B.1.617.2) and Omicron BA.1.1 sublineage (B.1.1.529) variants in a highly susceptible feline model of infection. While D614G- and Delta-inoculated cats became lethargic, and showed increased body temperatures between days 1 and 3 post-infection (pi), Omicron-inoculated cats remained subclinical and, similar to control animals, gained weight throughout the 14-day experimental period. Intranasal inoculation of cats with D614G- and the Delta variants resulted in high infectious virus shedding in nasal secretions (up to 6.3 log10 TCID 50 .ml -1 ), whereas strikingly lower level of viruses shedding (<3.1 log10 TCID 50 .ml -1 ) was observed in Omicron-inoculated animals. In addition, tissue distribution of the Omicron variant was markedly reduced in comparison to the D614G and Delta variants, as evidenced by in situ viral RNA detection, in situ immunofluorescence, and quantification of viral loads in tissues on days 3, 5, and 14 pi. Nasal turbinate, trachea, and lung were the main - but not the only - sites of replication for all three viral variants. However, only scarce virus staining and lower viral titers suggest lower levels of viral replication in tissues from Omicron-infected animals. Notably, while D614G- and Delta-inoculated cats had severe pneumonia, histologic examination of the lungs from Omicron-infected cats revealed mild to modest inflammation. Together, these results demonstrate that the Omicron variant BA.1.1 is less pathogenic than D614G and Delta variants in a highly susceptible feline model.
Author Summary:
The SARS-CoV-2 Omicron (B.1.1.529) variant of concern (VOC) emerged in South Africa late in 2021 and rapidly spread across the world causing a significant increase in the number of infections. Importantly, this variant was also associated with an increased risk of reinfections. However, the number of hospitalizations and deaths due to COVID-19 did not follow the same trends. These early observations, suggested effective protection conferred by immunizations and/or overall lower virulence of the highly mutated variant virus. In this study we present novel evidence demonstrating that the Omicron BA.1.1 variant of concern (VOC) presents a lower pathogenicity when compared to D614G- or Delta variants in cats. Clinical, virological and pathological evaluations revealed lower disease severity, viral replication and lung pathology in Omicron-infected cats when compared to D614G and Delta variant inoculated animals, confirming that Omicron BA.1.1 is less pathogenic in a highly susceptible feline model of infection.
Insights
The Omicron (B.1.1.529) variant of SARS-CoV-2 is less pathogenic in cats than earlier variants like D614G and Delta. Omicron-infected cats showed milder symptoms, reduced viral shedding, and less lung inflammation compared to those infected with D614G or Delta.
Area of Science:
- Virology
- Infectious Diseases
- Comparative Pathology
Background:
- The Omicron (B.1.1.529) variant of SARS-CoV-2 rapidly became globally dominant in early 2022.
- Early observations suggested Omicron infections might be less severe, despite increased transmission and reinfection rates.
Approach:
- This study utilized a susceptible feline model to compare the infection dynamics, tissue tropism, pathogenesis, and pathogenicity of SARS-CoV-2 D614G, Delta, and Omicron BA.1.1 variants.
- Cats were intranasally inoculated, and clinical signs, viral shedding, tissue distribution, and histopathology were evaluated post-infection.
Key Points:
- Omicron-inoculated cats remained subclinical, unlike D614G- and Delta-infected cats which showed lethargy and fever.
- Viral shedding in nasal secretions was significantly lower in Omicron-infected cats.
- Tissue distribution and viral replication were markedly reduced for the Omicron variant compared to D614G and Delta.
- Histological examination revealed mild lung inflammation in Omicron-infected cats, contrasting with severe pneumonia in cats infected with D614G and Delta variants.
Conclusions:
- The Omicron BA.1.1 variant demonstrates significantly lower pathogenicity than the D614G and Delta variants in a feline model.
- These findings in cats suggest a reduced potential for severe disease associated with the Omicron variant.
More Related Videos
08:41Live Imaging and Quantification of Viral Infection in K18 hACE2 Transgenic Mice Using Reporter-Expressing Recombinant SARS-CoV-2
Published on: November 5, 2021
06:08Author Spotlight: A Pseudotype Virus System for Assessing Omicron Subvariants and Neutralizing Antibodies in SARS-CoV-2 Research
Published on: September 8, 2023
Related Concept Videos
Single Nucleotide Polymorphisms-SNPs
Rabies
Coronavirus