Related Experiment Video
Updated: Sep 6, 2025

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial
Justin Chu1, Wen-Tse Yang1,2, Yao-Ting Chang3
1Research Center for Applied Sciences, Academia Sinica, 128 Academia Rd., Sec. 2, Nankang, Taipei City 115-29, Taiwan.
Abstract:
Atrial fibrillation (AFib) is a common type of arrhythmia that is often clinically asymptomatic, which increases the risk of stroke significantly but can be prevented with anticoagulation. The photoplethysmogram (PPG) has recently attracted a lot of attention as a surrogate for electrocardiography (ECG) on atrial fibrillation (AFib) detection, with its out-of-hospital usability for rapid screening or long-term monitoring. Previous studies on AFib detection via PPG signals have achieved good results, but were short of intuitive criteria like ECG p-wave absence or not, especially while using interval randomness to detect AFib suffering from conjunction with premature contractions (PAC/PVC). In this study, we newly developed a PPG flux (pulse amplitude) and interval plots-based methodology, simply comprising an irregularity index threshold of 20 and regression error threshold of 0.06 for the precise automatic detection of AFib. The proposed method with automated detection on AFib shows a combined sensitivity, specificity, accuracy, and precision of 1, 0.995, 0.995, and 0.952 across the 460 samples. Furthermore, the flux-interval plot configuration also acts as a very intuitive tool for visual reassessment to confirm the automatic detection of AFib by its distinctive plot pattern compared to other cardiac rhythms. The study demonstrated that exclusive 2 false-positive cases could be corrected after the reassessment. With the methodology's background theory well established, the detection process automated and visualized, and the PPG sensors already extensively used, this technology is very user-friendly and convincing for promoted to in-house AFib diagnostics.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias II: Classification of Tachyarrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias