Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
Pattarawan Ruangsuj1, Suwanan Wanthongcharoen1, Woraphan Chaisriratanakul2
1Program on Environmental Toxicology, Chulabhorn Graduate Institute, Chulabhorn Royal Academy, Bangkok 10210, Thailand.
Abstract:
In addition to their use as an additive to improve physical properties of solvent polymeric membranes, plasticizers have a considerable impact on the specificity and sensitivity of membrane-modified electrochemical sensors. In this work, we aim at the hybridization of two different plasticizers using the electropolymerization technique in the development of a cadmium(II)-selective electrochemical sensor based on screen-printed gold electrode along with cyclic voltammetric measurement. At this point, we first screen for the primary plasticizer yielding the highest signal using cyclic voltammetry followed by pairing it with the secondary plasticizers giving rise to the most sensitive current response. The results show that the hybridization of DOS and TOTM with 3:1 weight ratio (~137.7-μm-thick membrane) renders a signal that is >26% higher than that from the sensor plasticized by DOS per se in water. The solution of 0.1 mM hydrochloric acid (pH 4) is the optimal supporting electrolyte. In addition, hybrid plasticizers have adequate redox capacity to induce cadmium(II) transfer from bulk solution to the membrane/water interfaces. Conversion of voltammetric signals to semi-integral currents results in linearity with cadmium(II) concentration, indicating the irreversible cadmium(II) transfer to the membrane. The DOS:TOTM hybrid sensor also exhibits high sensitivity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 95 ppb and 288 ppb, respectively, as well as greater specificity towards cadmium(II) than that obtained from the single plasticizer sensor. Furthermore, recovery rates of spiked cadmium(II) in water samples were higher than 97% using the hybrid plasticizer sensor. Unprecedentedly, our work reports that the hybridization of plasticizers serves as ion-to-electron transducer that can improve the sensor performance in cadmium(II) detection.
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Complexometric Titration: Ligands
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...