Related Experiment Video
Updated: Sep 6, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Real-Time Temperature Monitoring under Thermal Cycling Loading with Optical Fiber Sensor
Shiuh-Chuan Her1, Jr-Luen Tasi1
1Department of Mechanical Engineering, Yuan Ze University, Chung-Li 320, Taoyuan 32003, Taiwan.
Abstract:
A fiber optic sensing system consisting of a fiber Bragg grating (FBG) sensor, optical circulator, optical band pass filter and photodetector is developed to monitor the real-time temperature response of a structure under a dynamic thermal loading. The FBG sensor is surface-bonded on a test specimen and integrated with an optical band pass filter. As a broadband light source transmits into a FBG sensor, a specific wavelength is reflected and transmitted into an optical band pass filter. The reflected wavelength is significantly affected by the temperature, while the output light power from the optical band pass filter is dependent on the wavelength. By measuring the light power with a photodetector, the wavelength can be demodulated, resulting in the determination of the temperature. In this work, the proposed optical sensing system was utilized to monitor the dynamic temperature change of a steel beam under a thermal cycling loading. To verify the accuracy of the fiber optic sensor, a thermocouple was adopted as the reference. The experimental results illustrate a good agreement between the fiber optic sensor and thermocouple. Electronic packages composed of various components such as a solder joint, silicon die, mold compound, and solder mask are frequently subjected to a thermal cycling loading in real-life applications. Temperature variations' incorporation with mismatches of coefficients of thermal expansion among the assembly components leads to crack growth, damage accumulation and final failure. It is important to monitor the temperature to prevent a thermal fatigue failure. A fast response and easy implementation of the fiber optic sensing system was proposed for the real-time temperature measurement under thermal cycling loading.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermal Stress
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...