Related Experiment Video
Updated: Sep 6, 2025

Use of Micro X-ray Computed Tomography with Phosphotungstic Acid Preparation to Visualize Human Fibromuscular Tissue
Published on: September 5, 2019
Phase-contrast enhanced synchrotron micro-tomography of human meniscus tissue
E Einarsson1, M Pierantoni2, V Novak3
1Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden; Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
Objective:
To investigate the feasibility of synchrotron radiation-based phase contrast enhanced micro-computed tomography (SR-PhC-μCT) for imaging of human meniscus. Quantitative parameters related to fiber orientation and crimping were evaluated as potential markers of tissue degeneration.
Design:
Human meniscus specimens from 10 deceased donors were prepared using different preparation schemes: fresh frozen and thawed before imaging or fixed and paraffin-embedded. The samples were imaged using SR-PhC-μCT with an isotropic voxel size of 1.625 μm. Image quality was evaluated by visual inspection and spatial resolution. Fiber voxels were defined using a grey level threshold and a structure tensor analysis was applied to estimate collagen fiber orientation. The area at half maximum (FAHM) was calculated from angle histograms to quantify orientation distribution. Crimping period was calculated from the power spectrum of image profiles of crimped fibers. Parameters were compared to degenerative stage as evaluated by Pauli histopathological scoring.
Results:
Image quality was similar between frozen and embedded samples and spatial resolutions ranged from 5.1 to 5.8 μm. Fiber structure, including crimping, was clearly visible in the images. Fibers appeared to be less organized closer to the tip of the meniscus. Fiber density might decrease slightly with degeneration. FAHM and crimping period did not show any clear association with histopathological scoring.
Conclusion:
SR-PhC-μCT is a feasible technique for high-resolution 3D imaging of fresh frozen meniscus tissue. Further work is needed to establish quantitative parameters that relate to tissue degeneration, but this imaging technique is promising for future studies of meniscus structure and biomechanical response.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

