Related Experiment Video
Updated: Sep 6, 2025

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Development of sol-gel silica-based mixed-mode zwitterionic sorbents for determining drugs in environmental water
Alberto Moral1, Francesc Borrull1, Kenneth G Furton2
1Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel·lí Domingo 1, Tarragona 43007, Spain.
Abstract:
Four novel mixed-mode zwitterionic silica-based functionalized with strong moieties sorbents were synthesized and evaluated through solid-phase extraction (SPE) to determine acidic and basic drugs in environmental water samples. All sorbents had the same functionalization: quaternary amine and sulfonic groups and C18 chains so that hydrophobic and strong cationic exchange (SCX) and strong anionic exchange (SAX) interactions could be exploited, in addition, two of them had carbon microparticles embedded. All sorbents retained both acidic and basic compounds in the preliminary assays but only the basic compounds were retained selectively through ionic exchange interactions when a clean-up step was introduced. The SPE method was therefore optimized to promote the selective retention of the basic compounds, initially with the two best-performing sorbents. After optimization of the SPE protocol, these sorbents were evaluated for the analysis of environmental water samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method with the best-performing sorbent was then validated with 100 mL of river samples and 50 mL of effluent wastewater samples in terms of apparent recoveries (%Rapp) spiking samples at 50 ng/L (river) and 200 ng/L (river and effluent), matrix effect, linear range, method quantification and detection limits, repeatability, and reproducibility. It should be highlighted that %Rapp ranged from 40 to 85% and matrix effects ranged from -17 to -4% for spiked river samples. When the method was applied to river and effluent wastewater samples, most compounds were found in the range from 24 to 1233 ng/L with detection limits from 1 to 5 ng/L.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
09:39Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination
Published on: March 1, 2020
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Analyte Adsorption and Distribution