Related Experiment Video
Updated: Sep 6, 2025

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Data on the clinical, analytical, and laboratory factors associated with negative anion gaps at an academic medical
Joseph M Laakman1, Zachary J Fleishhacker2, Matthew D Krasowski1
1Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA.
Abstract:
The anion gap is a calculated parameter derived from the difference between the major plasma cations and anions in serum/plasma or whole blood, with a widely used simple equation utilizing concentrations of sodium, chloride, and bicarbonate. While there is extensive literature on the clinical significance and causes of elevated anion gaps, there is comparatively less data on low anion gaps. Occasionally, anion gap calculations result in a negative number (-1 or less). From the published literature, causes of these 'negative anion gaps' include laboratory error, specimen contamination or interference, hypoalbuminemia, extreme hyperkalemia, bromism, and paraproteins from multiple myeloma or similar pathologic processes. The data in this article present results from retrospective review of clinical chemistry and blood gas analysis testing at an academic medical center. The data include electrolyte concentrations and anion gap values derived from a total of 2,948,574 specimens (2,841,863 serum/plasma specimens analyzed on Roche Diagnostics clinical chemistry analyzers, 93,987 whole blood specimens analyzed on Radiometer blood gas analyzers, and 12,724 whole blood specimens on point-of-care chemistry devices) from 371,925 unique patients, clinical area where testing was ordered (for serum/plasma samples), sex, and age. For serum/plasma specimens with a negative anion gap, the data additionally include information from detailed chart review of possible factors and disease conditions contributing to the negative anion gap, pattern of electrolyte abnormalities, presence or absence of hypoalbuminemia, and corrected anion gap (if hypoalbuminemia is present).
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Errors occurring during blood pressure monitoring
Several factors...
Barriers to Effective Communication II
Cultural barriers:
Differences in values, beliefs, religion, knowledge, and tradition can significantly impact communication. Awareness of nonverbal cues is critical, especially when conversing with a patient from a different culture. What appears appropriate in one culture may be inappropriate in another.
Semantic barriers:
As a result of their tendency to use...
Blank Solutions
In some experimental cases, the reagents, solvents, or lab equipment used in...
Urine Studies I: Urinalysis
Urine Studies II: Urine Culture and Sensitivity Test

