Related Experiment Video
Updated: Sep 6, 2025

Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound 30/45MHZ System
Published on: May 5, 2018
Ten Years of Data Verification: The European Congenital Heart Surgeons Association Congenital Database Audits
Claudia Herbst1, Zdzislaw Tobota2, Erhan Urganci1
1Department of Cardiac Surgery and Pediatric Heart Center, 27271Medical University Vienna, Vienna, Austria.
Background:
Congenital heart surgery databases are tools for internal programmatic evaluation, benchmarking institutional results to multi-institutional aggregate data, and research. Therefore, it is essential to ensure the completeness and accuracy of data. This study analyzes the results of ten years of on-site source data verification of the European Congenital Heart Surgeons Association Congenital Heart Surgery Database (ECHSA CHSD).
Methods:
All data forms verified between 2009 and 2018 were analyzed. The data form consists of 12 data elements: dates of birth, admission, surgery, discharge, and death; weight; case category; cardiopulmonary bypass time; aortic cross-clamp time; validation rules; diagnoses; and procedures. Descriptive data calculation and rates of completeness and accuracy were determined. The trend of error rate of seven centers with ≥5 visits was analyzed.
Results:
Sixty-nine on-site verification visits took place at 17 centers. A total of 26,245 cases were verified; 2,841 of these 26,245 cases (10.8%) showed an error. The total mean error rate of centers for all years was 12.3 ± 2.1%. Rates of completeness and accuracy were 99% and 89.2%, respectively. Coded diagnoses and procedure analysis revealed that 716 (2.7%) and 456 (1.7%) datasets were incorrect, respectively. Rates of completeness and accuracy of dates were 100%, and 97.1%, respectively. Validation fields showed no errors.
Conclusion:
Source data verification is an appropriate tool to determine completeness and accuracy of data. The ECHSA CHSD verification analysis of a ten-year period showed a high level of completeness and accuracy. The verified data of the ECHSA CHSD are well-suited for benchmarking and research.