Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Quantitative Gas Exchange in Extracorporeal Membrane Oxygenation-A New Device: Accuracy, Approach-based Difficulties,
Michael C Müller1, Sarah K Wilke1, Andrej Dobbermann1
1From the Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Anesthesiology and Operative Intensive Care Medicine.
Abstract:
Measurement of oxygen uptake (VO 2 ) and carbon dioxide removal (VCO 2 ) on membrane lungs (MLs) during extracorporeal membrane oxygenation (ECMO) provides potential for improved and safer therapy. Real-time monitoring of ML function and degradation, calculating caloric needs as well as cardiac output, and weaning algorithms are among the future possibilities. Our study compared the continuous measurement of the standalone Quantum Diagnostics System (QDS) with the published Measuring Energy Expenditure in ECMO patients (MEEP) approach, which calculates sequential VO 2 and VCO 2 values via blood gas analysis and a physiologic gas content model. Thirty-nine datasets were acquired during routine venovenous ECMO intensive care treatment and analyzed. VO 2 was clinically relevant underestimated via the blood-sided measurement of the QDS compared to the MEEP approach (mean difference -42.61 ml/min, limits of agreement [LoA] -2.49/-87.74 ml), which could be explained by the missing dissolved oxygen fraction of the QDS equation. Analysis of VCO 2 showed scattered values with wide limits of agreement (mean difference 54.95 ml/min, LoA 231.26/-121.40 ml/min) partly explainable by a calculation error of the QDS. We described potential confounders of gas-sided measurements in general which need further investigation and recommendations for enhanced devices.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...