Related Experiment Video
Updated: Sep 6, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Case report of a zygomatic bone hemangioma surgery with reconstruction by a custom-made implant
Louis-Joseph Laurian1, Suzanne Decaudaveine1, Aude Caillot1
1hospital practitioner at the Maxillofacial and oral surgery department of the Saint-Joseph hospital, 180 rue cardinet 75017 Paris, France.
Abstract:
Intraosseous hemangiomas are rare tumors. A 43-year-old woman was referred with a mass in the right zygomatic bone, showing a slow volume increase and pain symptomatology. A surgical management with bone reconstruction using a custom-made implant was decided. Historically, various autografts and alloplastic materials have been used for this type of bone loss. The use of custom-made biomaterials opens new possibilities in maxillofacial reconstructive surgery. The patient showed no symptoms postoperatively and her zygomatic bones were symmetrized. For the authors, this approach seems to be a reliable and reproducible method for zygomatic bone reconstructions.