Industry perspectives on the global use of validated blood pressure measuring devices
Jim Li1, Gerhard Frick2, Karel Herberigs3
1Omron Healthcare Co., Ltd., Kyoto, Japan. jim.li@omron.com.
Abstract:
A group of experts from reputable blood pressure measuring device (BPMD) manufacturers was invited to provide industry perspectives on the global use of validated BPMD. The authors support the recommendations of (1) using the consolidated universal ISO 81060-2:2018 in all future validation studies to ensure consistent and trustworthy quality standards; (2) validation studies to be led by investigators independent from the manufacturer; (3) validation study results to be published in peer-reviewed journals with an independent investigator as the corresponding author; and (4) validated BPMDs to be listed on validated device registries such as STRIDE BP, Validated Device Listing (VDL), and others that are backed by acknowledged scientific associations. The authors call for public awareness of the existence of legally marketed consumer BPMDs that lack sufficient evidence of clinical accuracy. Other important issues and future considerations were discussed, including the need: for awareness building and promoting the use of validated BPMDs among practitioners; to identify a non-mercury sphygmomanometer based reference device to validate BPMDs; to include all cuffs available for use with each BPMD in the validation study; for the promotion of validation studies for special patient populations; for validated wrist BPMDs as an alternative for some patients; for technical innovations to help reduce limitations related to the human aspect of validation studies; for validation of cuffless BPMDs; for validation through equivalency to validated base models; and to use validated BPMD in remote patient monitoring programs. A future collaborative to find solutions to support the use of validated BPMD is envisaged.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement