Related Experiment Video
Updated: Sep 6, 2025

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Study of alpha spectrometry for detection of radon and progeny using gas micro-strip detector
Mehdi Hassanpour1, Parvin Dehghanipour2, Mohammadreza Rezaie3
1Space Science Centre (ANGKASA), Institute of Climate Change (IPI), Universiti Kebangsaan Malaysia, Malaysia.
Abstract:
In this paper, simulation of a gas micro-strip detector by using the MCNPX code, the feasibility of alpha spectroscopy for radon and its progeny has been investigated. Initially, for the verification of the code, the range of alpha particles released from 222Rn gas in the air has been obtained in the standard condition, which is consistent with the experimental results. Subsequently, the energy loss per unit path length, range of alpha particles and radon progeny was measured, then the relationship between the range, the energy and the air pressure has been achieved. Finally, the simulation results have been compared with the results of the particle range relationship, pressure and energy, and the radon spectroscopy has been performed with the studied detector. The comparison of the spectrum obtained with the simulated micro-strip detector and the experimental results shows that the introduced micro-strip detector, in addition to the ability to measure radon and daughters, also has the ability to extract the spectrum from it.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...