Related Experiment Video
Updated: Sep 6, 2025

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
The importance of metrological tools to implementation of alternative method OECD TG 428
Luths R O Geaquinto1, Vanderléa Souza2, Eliane C P Rego3
1National Institute of Metrology, Quality and Technology (Inmetro), Postgraduate Program in Biotechnology, Av. Nossa Senhora das Graças, 50, Xerém, CEP 25250-020 Duque de Caxias, RJ, Brazil.
Abstract:
Usually, if percutaneous absorption tests are conducted in accordance with OECD Guideline 428, in vitro determination is accepted by mainly regulatory agencies. In this paper, we focus on the lack of comparability of the results regarding the permeation parameter/flow rate, although it is widely discussed in the literature. This work sought to evaluate the absorption of caffeine using Franz-type diffusion cell with porcine ear skin samples, varying the storage duration and the way to handle them. Metrological tools were used for caffeine quantification such as certified reference material candidate, calibrated instruments, and validated methodology. Our results corroborate with the recommendation that membranes should be freshly prepared or frozen for short periods. Samples frozen for approximately one year should not be used because they present high cutaneous absorption. The results obtained for the absorption rate (J) are comparable to the results obtained by previous studies using similar experimental conditions. The evidence of the barrier characteristic promoted by the stratum corneum and the effect promoted by the storage time is shown through J = 6.25 ± 0.48 μg/cm2/h. We demonstrated the importance of metrological tools to guarantee reproducibility and comparability of the results between different laboratories.
More Related Videos
07:08Nanoparticle Tracking Analysis of Gold Nanoparticles in Aqueous Media through an Inter-Laboratory Comparison
Published on: October 20, 2020
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Data Validation
Key parameters for method validation include:
Microbial Growth Measurement: Indirect Methods
Development of Analytical Methods
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Uncertainty in Measurement: Reading Instruments