Related Experiment Video
Updated: Sep 6, 2025

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Effects of environmental condition, size, coat type, and body condition score on rectal temperature prediction in
Yanisa Lukkanawaraporn1, Nutnicha Tiangtas1, Vorapan Chaikornkij1
1Faculty of Veterinary Medicine, Kasetsart University, Bangkok 10900, Thailand.
Background And Aim:
Generally, rectal body temperature (BTrectum) is used to prefer as core body temperature in dogs. However, this procedure is time- and labor-consuming with stress induction. Therefore, infrared auricular temperature (BTear) and surface temperature (ST) could be applied to estimate BTrectum. This study aimed to estimate BTrectum from BTear or ST in various areas and determined the factors that influenced the accuracy of prediction equations.
Materials And Methods:
Under controlled temperature (n=197) and ambient temperature (n=183), the parameters BTrectum, BTear, and ST at internal pinna, auricular canal, lateral aspect of shoulder, hip, axillary area, inguinal area, footpad, and anal area (STrectum) were measured. In addition, temperature and humidity levels of the surrounding environment were recorded. The correlation between each measurement technique was calculated. The BTrectum prediction equation was created using all measured data and several influencing factors (environmental condition, size, coat type, and body condition score [BCS]).
Results:
The highest correlation with BTrectum was observed for BTear (r=0.61, p<0.01), which was similar to STrectum (r=0.61, p<0.01). Based on multiple linear regression model results using BTrectum as the dependent variable, BTear or STrectum were first selected as independent variables in all estimation equations. Ambient temperatures (R2=0.397), small breed (R2=0.582), long hair (R2=0.418), and/or a BCS of 2 (R2=0.557) provided the highest coefficients of determination of the prediction equation.
Conclusion:
The most appropriate predictors for estimating BTrectum were STrectum and BTear, which were impacted by the dog's signalments and the environment. To obtain satisfactory outcomes, the equation must be selected depending on the dog's signalments and the environmental conditions. However, based on the findings of this investigation, the accuracy remains low in several equations, and further studies are needed to improve the accuracy of the equation, mainly by increasing the sample size and developing a specific equation for each dog's signaling and environmental condition.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...