Related Experiment Video
Updated: Sep 6, 2025

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet
Published on: November 2, 2020
Inactivation of Escherichia coli by atmospheric pressure plasma jet in water
Mehdi Bakhshzadmahmoudi1, Nader Morshedian1, Ahmad Mehramiz2
1Plasma and Nuclear Fusion Research School, Nuclear Science and Technologies Institute, Tehran, Iran
Abstract:
The main aim of this work is inactivation of Escherichia coli in water using a laboratory-scale radio-frequency atmospheric pressure Argon plasma jet. This bacterium is widely present in the environment, especially in drinking water, and its pathogenic effects are very harmful. For this purpose, an Argon flow rate of 3.5 slm, maximum plasma power of 200 W, and discharge frequency of 13.56 MHz was conducted to generate a uniform plasma plume for water treatment. 150 ml of drinking water contaminated by E. coli was exposed to the radiation of plasma placed about 3 cm within the water, the treatment time varied from 2 to 6 minutes at 100, 150, and 200 W of plasma input power. The temperature of the plume, discharge current and voltage, and electron density were all measured to characterize the plasma. Active species such as excited molecules, ions, and radicals produced in the plasma in water were detected using the optical emission spectroscopy method. The decreasing behavior of live bacteria versus exposure time and plasma jet input power was observed, and finally, at the discharge power of 200 W and 6 min, an effective inactivation was achieved and the number of bacteria reduced from 92×104 to less than 1.7 MPN/100 ml.
More Related Videos
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
08:36An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation
Published on: November 3, 2016
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Atomic Emission Spectroscopy: Overview