Related Experiment Video
Updated: Sep 6, 2025

Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Defining electrocardiographic criteria to differentiate non-type 1 Brugada ECG variants from normal incomplete RBBB
Mafalda Carrington1, Antonio Creta2, William J Young2,3
1Cardiology Department, Hospital do Espírito Santo de Évora, Évora, Portugal.
Introduction:
We assessed the prevalence of non-type 1 Brugada pattern (T1BrP) in children and young adults from the Sudden Cardiac Death-Screening Of risk factorS cohort and the diagnostic yield of nonexpert manual and automatic algorithm electrocardiogram (ECG) measurements.
Methods:
Cross-sectional study. We reviewed 14 662 ECGs and identified 2226 with a rSr'-pattern in V1-V2. Among these, 115 were classified by experts in hereditary arrhythmic-syndromes as having or not non-T1BrP, and were compared with measurements of 5 ECG-derived parameters based on a triangle formed by r' -wave (d(A), d(B), d(B)/h, β-angle) and ST-ascent, assessed both automatically and manually by nonexperts. We estimated intra- and interobserver concordance for each criterion, calculated diagnostic accuracy and defined the most appropriate cut-off values.
Results:
A rSr'-pattern in V1-V2 was associated with higher PQ interval and QRS duration, male gender, and lower body mass index (BMI). The manual measurements of non-T1BrP criteria were moderately reproducible with high intraobserver and moderate interobserver concordance coefficients (ICC: 0.72-0.98, and 0.63-0.76). Criteria with higher discriminatory capacity were: distance d(B) (0.72; 95% confidence interval [CI]: 0.65-0.80) and ST-ascent (0.87; 95% CI: 0.82-0.92), which was superior to the 4 r'-wave criteria together (area under curve [AUC: 0.74]). We suggest new cut-offs with improved combination of sensitivity and specificity: d(B) ≥ 1.4 mm and ST-ascent ≥ 0.7 mm (sensitivity: 1%-82%; specificity: 71%-84%), that can be automatically measured to allow classification in four morphologies with increasing non-T1BrP probability.
Conclusion:
rSr'-pattern in precordial leads V1-V2 is a frequent finding and the detection of non-T1BrP by using the aforementioned five measurements is reproducible and accurate. In this study, we describe new cut-off values that may help untrained clinicians to identify young individuals who may require further work-up for a potential Brugada Syndrome diagnosis.
More Related Videos
06:07Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
Published on: May 23, 2021
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias II: Classification of Tachyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias