Related Experiment Video
Updated: Sep 6, 2025

CO2-Lasertonsillotomy Under Local Anesthesia in Adults
Published on: November 6, 2019
Microlaryngeal Laser Surgery Using High-flow Nasal Ventilation at Two Oxygen Concentration Deliveries
Daniel Novakovic1,2, Meet Sheth1,3, Avital Fellner1,4
1Voice Research Laboratory, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia.
Objectives:
Ventilation using 100% oxygenation creates a risk of fire during laser microlaryngeal surgery (MLS). The purpose of this study is to describe the technique of transnasal high-flow ventilation using laser safe (30%) oxygen conditions, measure the intraoperative real-time laryngeal oxygen concentration, and examine patient saturation status using this technique.
Methods:
Prospective IRB approved study of patients undergoing tubeless laser MLS using high-flow nasal oxygenation. Delivered oxygen concentration was reduced from 100% to 30% before lasering using an oxygen-air blender then increased to 100% post-laser procedure. Outcome measures included time for laryngeal oxygen concentration to equalize to laser safe levels; time to, methods of and duration of rescue ventilation; and desaturation rates and apnoeic times at both 100% and 30% oxygen deliveries.
Results:
Fifty patients were recruited (mean age = 47.4 years). Mean laryngeal oxygen concentration (%) at 100% and 30% deliveries was 98.46 and 31.45, respectively. Mean (SD) of laryngeal oxygen concentration equalization time to 30% (seconds) was 9.4 (3.69). At 30% oxygen delivery desaturation rate was faster and apneic time shorter compared with 100%. Eighteen patients required rescue (jet) ventilation and they had a faster apneic desaturation rate (%/minute) than patients not requiring rescue. Mean (SD) apneic time (minutes) at 30% delivery was 4.56 (2.25) and 4.41 (2.18) in rescue versus non-rescue groups respectively. BMI was the only significant predictor of desaturation rate at 30% oxygen delivery.
Conclusion:
It is possible to achieve a safe time window for use of laser during MLS using transnasal humidified high-flow ventilation by delivering 30% oxygen concentration.
Level Of Evidence:
4 Laryngoscope, 133:634-639, 2023.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...