Related Experiment Video
Updated: Sep 6, 2025

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Determination of a reliable assessment for occupational eye lens dose in nuclear medicine
Noriaki Miyaji1, Kenta Miwa2, Takashi Iimori3
1Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.
Abstract:
The most recent statement published by the International Commission on Radiological Protection describes a reduction in the maximum allowable occupational eye lens dose from 150 to 20 mSv/year (averaged over 5-year periods). Exposing the eye lens to radiation is a concern for nuclear medicine staff who handle radionuclide tracers with various levels of photon energy. This study aimed to define the optimal dosimeter and means of measuring the amount of exposure to which the eye lens is exposed during a routine nuclear medicine practice. A RANDO human phantom attached to Glass Badge and Luminess Badge for body or neck, DOSIRIS and VISION for eyes, and nanoDot for body, neck, and eyes was exposed to 99m Tc, 123 I, and 18 F radionuclides. Sealed syringe sources of each radionuclide were positioned 30 cm from the abdomen of the phantom. Estimated exposure based on measurement conditions (i.e., air kerma rate constants, conversion coefficient, distance, activity, and exposure time) was compared measured dose equivalent of each dosimeter. Differences in body, neck, and eye lens dosimeters were statistically analyzed. The 10-mm dose equivalent significantly differed between the Glass Badge and Luminess Badge for the neck, but these were almost equivalent at the body. The 0.07-mm dose equivalent for the nanoDot dosimeters was greatly overestimated compared to the estimated exposure of 99m Tc and 123 I radionuclides. Measured dose equivalents of exposure significantly differed between the body and eye lens dosimeters with respect to 18 F. Although accurately measuring radiation exposure to the eye lenses of nuclear medicine staff is conventionally monitored using dosimeters worn on the chest or abdomen, eye lens dosimeters that provide a 3-mm dose equivalent near the eye would be a more reliable means of assessing radiation doses in the mixed radiation environment of nuclear medicine.
Related Concept Videos
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

