Changes in effective optical zone after small-incision lenticule extraction in high myopia
Lixia Sun1, Hui-Ni Lin1, Vishal Jhanji2,3,4
1Joint Shantou International Eye Center of Shantou University, The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China.
Four methods for determining the effective optical zone (EOZ) after small-incision lenticule extraction surgery in high myopia eyes all showed reduced EOZs compared to the planned optical zone (POZ). Vertex-based (EOZV) and pupil-based (EOZP) methods were closest to POZ.
Area of Science:
- Ophthalmology
- Corneal Refractive Surgery
- Ophthalmic Imaging
Background:
- Small-incision lenticule extraction (SMILE) is a common refractive surgery for high myopia.
- Accurate determination of the effective optical zone (EOZ) is crucial for optimizing visual outcomes and minimizing aberrations after SMILE.
- Scheimpflug tomography provides detailed corneal measurements essential for EOZ assessment.
Purpose of the Study:
- To compare and evaluate four distinct measurement approaches for determining the effective optical zone (EOZ) after SMILE surgery in eyes with high myopia.
- To assess the consistency and clinical applicability of vertex-based (EOZV), pupil-based (EOZP), 4 mm-ring-based total corneal refraction (EOZ4), and tangential curvature difference map (EOZD) methods.
Main Methods:
- A retrospective cohort study involving 74 subjects who underwent SMILE for high myopia.
- EOZ was measured 3 months postoperatively using four different methods: EOZV, EOZP, EOZ4, and EOZD.
- Comparisons were made between the measured EOZs and the planned optical zone (POZ), with analysis of eccentricity, ablation degree, and corneal aberrations.
Main Results:
- All four EOZ measurement methods revealed a reduction in EOZ compared to the POZ (6.48 ± 0.16 mm).
- Measured EOZs were: EOZV (5.87 ± 0.44 mm), EOZP (5.85 ± 0.45 mm), EOZ4 (4.78 ± 0.40 mm), and EOZD (5.29 ± 0.27 mm).
- Bland-Altman analysis indicated good consistency among the four EOZs, with EOZV and EOZP showing the smallest difference (0.02 mm).
Conclusions:
- All evaluated methods confirm a reduction in the effective optical zone post-SMILE surgery compared to the planned optical zone.
- The vertex-based (EOZV) and pupil-based (EOZP) methods demonstrated the closest agreement with the planned optical zone.
- Differences in EOZs did not show significant correlations with eccentricity, ablation degree, or corneal aberrations.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
10:10Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
Published on: February 15, 2022
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...