Related Experiment Video
Updated: Sep 5, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Polymerization shrinkage and shrinkage stress of bulk-fill and non-bulk-fill resin-based composites
Peng Yu1,2, Yong-Xiang Xu2,3, Yu-Shu Liu2,4
1Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing, China.
Background/Purpose:
Bulk-fill resin-based composites (RBCs) are a new class of restorative materials, and polymerization shrinkage (PS) is concerned due to their single increment up to 4 mm. The aim of this study was to evaluate the PS and shrinkage stress (SS) of bulk-fill RBCs in vitro.
Materials And Methods:
Three bulk-fill RBCs and three conventional non-bulk-fill RBCs were selected. The PS was determined with Acuvol volumetric shrinkage analyzer by calculating the specimen volume variation before and after light irradiation. The SS was investigated using universal testing machine method with a polymethyl methacrylate rod as a bonding substrate. The force generated during the polymerization process was detected by a load cell linked to a computer. SS was calculated by dividing the maximum stress force by the area of the rod.
Results:
The mean PS of various RBCs ranged from 1.72% to 2.13%. All PS results of bulk-fill RBCs were comparable to their conventional counterparts. Sonicfill 2 (SF2) and Harmonize (HM) showed the lowest PS (p < 0.05; Tukey HSD test). Medians of SS results ranged from 0.55 MPa to 0.67 MPa. All SSs of bulk-fill RBCs were comparable to their conventional counterparts. SF2 showed significantly lower SS than Tetric N-Ceram (TN) and Tetric N-Ceram Bulk Fill (TNB) (p < 0.0083; post hoc comparisons with Bonferroni adjustments). A moderate, positive correlation was observed between PS and SS with Pearson's correlation (r = 0.446, p = 0.013).
Conclusion:
Both PS and SS are material dependent. A moderate, positive correlation between PS and SS is found with new bulk-fill RBCs and their conventional counterparts.
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Plastic Behavior
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Residual Stresses