Related Experiment Video
Updated: Sep 5, 2025

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Evaluations of Repaired Artery Patency in Forearm Wounds Using the Allen Test, Handheld Doppler and Doppler
Amanda Favaro Cagnolati1, Fernanda Ruiz Andrade1, Sara Dadona Correia Serrano2
1Residência Médica em Cirurgia de Mão, Departamento de Ortopedia e Anestesiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brasil.
Abstract:
Objective The purpose of the present study was to evaluate the rate of patency in the postoperative period of arterial injuries of the forearm secondary to penetrating trauma. The injuries were subjected to primary repair and examined with the Allen test and a handheld Doppler device, and the results were later confirmed with Doppler ultrasonography. Methods Eighteen patients were included, with a total of 19 arterial lesions, 14 ulnar lesions, and 5 radial lesions; one patient had lesions on both forearms. All patients underwent surgery and three clinical evaluations: the Allen test and assessment of arterial blood flow by a handheld Doppler device at 4 and 16 weeks after surgery and Doppler ultrasonography performed at 12 weeks after surgery. Results At the first clinical evaluation, 77% of the patients had patency based on the Allen test, and 72% had a pulsatile sound identified by the handheld Doppler device. In the second evaluation, 61% of the patients had patency based on the Allen test, and the rate of pulsatile sound by the handheld Doppler device was 72%, similar to that observed 2 months earlier. Based on the Doppler ultrasonography evaluation (∼12 weeks after surgery), the success rate for arteriorrhaphy was 88%. Regarding the final patency (Doppler ultrasonography evaluation) and trauma mechanism, all patients with penetrating trauma had patent arteries. Conclusion We conclude that clinical evaluation using a handheld Doppler device and the Allen test is reliable when a patent artery can be palpated. However, if a patent artery cannot be located during a clinical examination, ultrasonography may be required.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement

