Related Experiment Video
Updated: Sep 5, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Adaptation of removable partial denture rest seats in prostheses made with selective laser sintering or casting
Samuel Pelletier1, Annik Pelletier2, Ghassan Al Dika2
1Masters student in Dental Science, Department of General Dentistry, Faculty of Dental Medicine of Laval University, Québec, Canada; and Private practice, Montreal, Quebec, Canada.
Statement Of Problem:
New fabrication techniques have been developed for removable partial denture (RPD) frameworks although studies validating the clinical application of these techniques are scarce.
Purpose:
The purpose of this clinical study was to compare the adaptation of RPD framework rests made with conventional casting or computer-aided design and computer-aided manufacturing (CAD-CAM) with selective laser sintering (SLS) at the clinical evaluation and 1 year after the delivery of the prostheses.
Material And Methods:
This triple-blinded pilot study included 18 participants presenting with maxillary and/or mandibular partial edentulism, of which only 7 returned for the second measurement 1 year after prosthesis delivery. Participants were randomly assigned to 1 of 2 groups depending on whether the RPD framework was made with SLS or conventional lost-wax casting. The adaptation of the RPD at the rest seat area was evaluated by injecting a silicone material on the abutment tooth before seating. The silicone specimens were then sectioned transversely and measured with a scanning electron microscope. The statistical analysis was performed with a linear mixed-effect model with the intention to treat and with a 3-factor repeated measures ANOVA (α=.05).
Results:
At the metal framework evaluation (T0), the prostheses made with SLS showed a mean ±standard deviation adaptation of 398 ±45 μm, while those made with conventional casting presented a mean ±standard deviation adaptation of 176 ±41 μm (P=.009). One year after the delivery of the prostheses (T1), the adaptation of the frameworks made with conventional casting was still significantly better (88 ±6 μm versus 197 ±94 μm, P=.03).
Conclusions:
Frameworks made with SLS showed worse clinical accuracy at the rest than frameworks produced with conventional casting.