Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Effects of tonotopic matching and spatial cues on segregation of competing speech in simulations of bilateral
Mathew Thomas1, Shelby Willis1, John J Galvin2
1Department of Head and Neck Surgery, David Geffen School of Medicine, UCLA, Los Angeles, CA, United States of America.
Abstract:
In the clinical fitting of cochlear implants (CIs), the lowest input acoustic frequency is typically much lower than the characteristic frequency associated with the most apical electrode position, due to the limited electrode insertion depth. For bilateral CI users, electrode positions may differ across ears. However, the same acoustic-to-electrode frequency allocation table (FAT) is typically assigned to both ears. As such, bilateral CI users may experience both intra-aural frequency mismatch within each ear and inter-aural mismatch across ears. This inter-aural mismatch may limit the ability of bilateral CI users to take advantage of spatial cues when attempting to segregate competing speech. Adjusting the FAT to tonotopically match the electrode position in each ear (i.e., increasing the low acoustic input frequency) is theorized to reduce this inter-aural mismatch. Unfortunately, this approach may also introduce the loss of acoustic information below the modified input acoustic frequency. The present study explored the trade-off between reduced inter-aural frequency mismatch and low-frequency information loss for segregation of competing speech. Normal-hearing participants were tested while listening to acoustic simulations of bilateral CIs. Speech reception thresholds (SRTs) were measured for target sentences produced by a male talker in the presence of two different male talkers. Masker speech was either co-located with or spatially separated from the target speech. The bilateral CI simulations were produced by 16-channel sinewave vocoders; the simulated insertion depth was fixed in one ear and varied in the other ear, resulting in an inter-aural mismatch of 0, 2, or 6 mm in terms of cochlear place. Two FAT conditions were compared: 1) clinical (200-8000 Hz in both ears), or 2) matched to the simulated insertion depth in each ear. Results showed that SRTs were significantly lower with the matched than with the clinical FAT, regardless of the insertion depth or spatial configuration of the masker speech. The largest improvement in SRTs with the matched FAT was observed when the inter-aural mismatch was largest (6 mm). These results suggest that minimizing inter-aural mismatch with tonotopically matched FATs may benefit bilateral CI users' ability to segregate competing speech despite substantial low-frequency information loss in ears with shallow insertion depths.
More Related Videos
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
Related Concept Videos
The Cochlea
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...