Related Experiment Video
Updated: Sep 5, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of multiple firings on surface roughness and flexural strength of CAD-CAM ceramics
Meryem Gülce Subaşı1, Gülce Çakmak2, Murat Sert3
1Associate Professor, Department of Prosthodontics, Kutahya Saglik Bilimleri University, Faculty of Dentistry, Kütahya, Turkey.
Statement Of Problem:
Knowledge on the effect of multiple firings on surface roughness and the flexural strength of different types of monolithic computer-aided design and computer-aided manufacturing (CAD-CAM) ceramics is limited.
Purpose:
The purpose of this in vitro study was to evaluate the effect of multiple firings on the surface roughness and flexural strength of 4 different CAD-CAM ceramics after thermocycling.
Material And Methods:
Four different CAD-CAM ceramics (Lava All Zirconia 3-mol yttria tetragonal zirconia polycrystal [3-YTZP] [Z], VITA SUPRINITY [S], IPS e.max CAD [EX], IPS Empress CAD [E]) (n=33) were wet-sectioned to form rectangular 18×4×1.2-mm specimens. After glaze application, the specimens were divided into 3 subgroups according to the number of firings (1, 2, and 4) (n=11). The specimens were thermocycled (10 000 cycles), and surface roughness and flexural strength values were measured (n=10). One additional specimen from each group was analyzed by using scanning electron microscopy (SEM). Data were analyzed by 2-way analysis of variance (ANOVA) and the Tukey honestly significance difference (HSD) test (α=.05).
Results:
According to the 2-way ANOVA, the material, number of firings, and the interaction between the material and number of firings affected the surface roughness (P<.001). For flexural strength, material (P<.001) and number of firings (P<.039) were found significant. Multiple firings (2 or 4 firings) affected the surface roughness of E (P<.001). Regardless of the number of firings, the Z material had the highest flexural strength (P<.001). Four firings affected the flexural strength values only for the Z material (P≤.005).
Conclusions:
CAD-CAM ceramic type affected the surface roughness and flexural strength values. The surface roughness of E was lower when fired 2 or 4 times than when fired once. The flexural strength of Z was lower when fired 4 times than when fired once.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to...
Fineness of Cement
Direct...

