Related Experiment Video For Raman spectroscopy
Updated: Sep 5, 2025

A Multimodal Imaging Framework to Advance Phenotyping of Living Label-free Breast Cancer Cells
Published on: August 22, 2025
Diagnosing molecular subtypes of breast cancer by means of Raman spectroscopy
Alexandre S Melitto1, Victor E A Arias2, Jorge Y Shida2
1Mastology Department, CRSM-Hospital Pérola Byington, São Paulo, SP, Brazil.
Objectives:
Raman spectroscopy has been used to discriminate human breast cancer and its different tumor molecular subtypes (luminal A, luminal B, HER2, and triple-negative) from normal tissue in surgical specimens.
Materials And Methods:
Breast cancer and normal tissue samples from 31 patients were obtained by surgical resection and submitted for histopathology. Before anatomopathological processing, the samples had been submitted to Raman spectroscopy (830 nm, 25 mW excitation laser parameters). In total, 424 Raman spectra were obtained. Principal component analysis (PCA) was used in an exploratory analysis to unveil the compositional differences between the tumors and normal tissues. Discriminant models were developed to distinguish the different cancer subtypes by means of partial least squares (PLS) regression.
Results:
PCA vectors showed spectral features referred to the biochemical constitution of breast tissues, such as lipids, proteins, amino acids, and carotenoids, where lipids were decreased and proteins were increased in breast tumors. Despite the small spectral differences between the different subtypes of tumor and normal tissues, the discriminant model based on PLS was able to discriminate the spectra of the breast tumors from normal tissues with an accuracy of 97.3%, between luminal and nonluminal subtypes with an accuracy of 89.9%, between nontriple-negative and triple-negative with an accuracy of 94.7%, and each molecular subtype with an accuracy of 73.0%.
Conclusion:
PCA could reveal the compositional difference between tumors and normal tissues, and PLS could discriminate the Raman spectra of breast tissues regarding the molecular subtypes of cancer, being a useful tool for cancer diagnosis.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...