Related Experiment Video
Updated: Sep 5, 2025

A Two-interval Forced-choice Task for Multisensory Comparisons
Published on: November 9, 2018
Electrophysiological correlates of confidence differ across correct and erroneous perceptual decisions
Daniel Feuerriegel1, Mackenzie Murphy1, Alexandra Konski1
1Melbourne School of Psychological Sciences, The University of Melbourne, Redmond Barry Building, Melbourne 3010, Australia.
Abstract:
Every decision we make is accompanied by an estimate of the probability that our decision is accurate or appropriate. This probability estimate is termed our degree of decision confidence. Recent work has uncovered event-related potential (ERP) correlates of confidence both during decision formation and after a decision has been made. However, the interpretation of these findings is complicated by methodological issues related to ERP amplitude measurement that are prevalent across existing studies. To more accurately characterise the neural correlates of confidence, we presented participants with a difficult perceptual decision task that elicited a broad range of confidence ratings. We identified a frontal ERP component within an onset prior to the behavioural response, which exhibited more positive-going amplitudes in trials with higher confidence ratings. This frontal effect also biased measures of the centro-parietal positivity (CPP) component at parietal electrodes via volume conduction. Amplitudes of the error positivity (Pe) component that followed each decision were negatively associated with confidence for trials with decision errors, but not for trials with correct decisions, with Bayes factors providing moderate evidence for the null in the latter case. We provide evidence for both pre- and post-decisional neural correlates of decision confidence that are observed in trials with correct and erroneous decisions, respectively. Our findings suggest that certainty in having made a correct response is associated with frontal activity during decision formation, whereas certainty in having committed an error is instead associated with the post-decisional Pe component. These findings also highlight the possibility that some previously reported associations between decision confidence and CPP/Pe component amplitudes may have been a consequence of ERP amplitude measurement-related confounds. Re-analysis of existing datasets may be useful to test this hypothesis more directly.
More Related Videos
09:00Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex
Published on: April 15, 2015
07:37Assessment and Communication for People with Disorders of Consciousness
Published on: August 1, 2017
Related Concept Videos
Cause and Effect
Confirmation Biases
Factors Affecting Perception
An illustrative example of a perceptual set is the scenario where an airline pilot told...
Perceptual Constancy
Size constancy is the recognition that an object remains the same size, even when its image on the retina changes. For instance, a bus is perceived to be large enough to carry people, even if it looks tiny from...
Confidence Coefficient
Hindsight Biases