Objectives:
Noninvasive high-frequency oscillatory ventilation (nHFOV) is a novel respiratory support mode for premature infants. This retrospective study aimed to compare the effect of nHFOV and bi-level nasal continuous positive airway pressure (BiPAP) in premature infants with neonatal respiratory failure (NRF) as initial noninvasive ventilation (NIV) support mode.
Methods:
We retrospectively analyzed medical records of preterm infants admitted to the tertiary neonatal intensive care units (NICUs) of Fujian Maternal and Child Health Hospital from January 2019 to December 2020. Preterm infants with the gestational age of 25-34 weeks, diagnosed with NRF, used nHFOV or BiPAP as the initial respiratory support mode were analyzed. The rates of invasive mechanical ventilation (IMV) within the first seven days after birth and adverse outcomes were compared between the two groups.
Results:
Two hundred fifty-five preterm infants were analyzed (128 in nHFOV group,127 in BiPAP group). There was no significant difference in baseline characteristics between the two groups. Compared with the BiPAP group, the nHFOV group had significantly lower need for IMV within the first seven days after birth (18/128 vs. 33/127, p = 0.01) and PCO2 at 12 and 24 hours post-treatment (46.34±5.24mmHg vs. 51.18±4.83mmHg, P<0.01; 40.72±4.02mmHg vs. 42.50±3.86mmHg, P<0.01). The incidence of BPD, ROP, air leak syndromes, IVH≥ grade 3, PVL, NEC≥II stage, abdominal distension, and nasal trauma were similar between the two groups.
Conclusion:
nHFOV significantly reduced the need for IMV and improved the elimination of CO2 compared with BiPAP in preterm infants with NRF without increasing the incidence of adverse effects.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: