Related Experiment Video
Updated: Sep 5, 2025
![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)
Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941
Published on: April 28, 2019
Synthesis and Preclinical Evaluation of [11C]AZ11895530 for PET Imaging of the Serotonin 1A Receptor
Kenneth Dahl1,2, Peter Johnström3,4, Anton Forsberg-Morén3
1Department of Radiopharmacy, Karolinska University Hospital, SE-171 76 Stockholm, Sweden.
Abstract:
The serotonin 1A (5-HT1A) receptor is a G-protein-coupled receptor implicated in the pathophysiology of several neuropsychiatric and neurodegenerative disorders. We here report the preparation of two candidate 5-HT1A radioligands, [11C]AZ11132132 ([11C]3) and [11C]AZ11895530 ([11C]4), and their subsequent evaluation in vitro using autoradiography and in vivo using positron emission tomography (PET). Compounds 3 and 4 were radiolabeled at high radiochemical purity (>99%) and high molar activity (>38 GBq/μmol) by heteroatom methylation with [11C]methyl iodide. Autoradiography on whole hemispheres from post-mortem human brain revealed substantial nonspecific binding of [11C]3, while the binding of [11C]4 to brain tissue was consistent with the distribution of 5-HT1A receptors and sensitive to co-incubation with the reference 5-HT1A antagonist WAY-100635 (10 μM). Following intravenous injection of [11C]4 into a cynomolgus monkey, brain radioactivity concentration (Cmax ∼ 2.2 SUV) was high whereafter it decreased rapidly. The regional binding potential (BPND) values were calculated using the simplified reference tissue model with cerebellum as reference region. The values varied between 0.2 and 1.0 for temporal cortex, raphe nuclei, frontal cortex, and hippocampus which is consistent with the known 5-HT1A expression pattern. After pretreatment with WAY100635 (0.5 mg/kg), a homogeneous distribution of radioactivity was observed in non-human primate (NHP) brain. Although [11C]4 fulfilled important criteria for successful in vivo neuroimaging, including good blood-brain-barrier permeability and high specific binding in vitro to human brain tissue, the regional BPND values for [11C]4 in NHP brain were low when compared to those obtained with existing radioligands and thus do not merit further investigation of [11C]4. Evaluation of structurally related analogues is underway in our laboratory to identify improved candidates for clinical imaging.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

