Related Experiment Video
Updated: Sep 5, 2025

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Development of Narrow-Bore C18 Column for Fast Separation of Peptides and Proteins in High-Performance Liquid
Ashraf Ali1, Sarah Alharthi2, Nora Hamad Al-Shaalan3
1Department of Chemistry, Faculty of Natural Sciences, University of Haripur, Haripur 22062, Khyber Pakhtunkhwa, Pakistan.
Abstract:
Separation with high efficiency and good resolution is constantly in demand in the pharmaceutical industry. The fast and efficient separation of complex samples such as peptides and proteins is a challenging task. To achieve high efficiency with good resolution, chromatographers are moving towards small particles packed into narrow-bore columns. Silica monolith particles (sub-2 µm) were derivatized with chlorodimethyl octadecyl silane (C18) and packed into stainless steel columns (100 mm × 1.8 mm i.d) by a slurry-packing method. The developed columns were used for the separation of peptides and proteins. A separation efficiency (N) of 40,000 plates/column (400,000 plates/m) was achieved for the mixture of five peptides. Similarly, the fast separation of the peptides was carried out using a high flow rate, and the separation of the five peptides was achieved in one minute with high efficiency (N ≅ 240,000 plates/m). The limit of detection (DL) and the limit of quantification (QL) for each analyte were determined by developing a linear regression curve with relatively very low concentrations of the target compound. The average values of the QL for the peptide and proteins were 0.55 ng and 0.48 ng, respectively, using short C18 column (1.8 mm × 100 mm) UV (at 214 nm). The fast analysis of peptides and proteins with such high efficiency and good resolution has not been reported in the literature yet. Owing to high efficiency, these home-made columns could be used as an alternative to the expensive commercial columns for peptide and protein separation.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...

