Related Experiment Video
Updated: Sep 5, 2025

Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Separation of planar chiral ferrocenes by capillary electrokinetic chromatography and liquid chromatography
Antoine Morvan1, Camille Garnier1, Christophe Furman1
1Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France.
Abstract:
Capillary electrokinetic chromatography (CEKC) and liquid chromatography (LC) methods were explored for the enantiomeric separation of six unsymmetrically disubstituted ferrocene derivatives. In normal-phase mode liquid chromatography, the use of n-heptane, ethanol or isopropanol with 1% n-butylamine as mobile phase on six polysaccharide-based columns, allowed to fully separate the enantiomers of three compounds out of the six (i.e 7-chloro-N-(2-((dimethylamino)methyl)ferrocenyl)quinolin-4-amine (ferroquine) (compound 1), 1-[(1S)-(1-Aminoethyl)]-2-(diphenylphosphino)ferrocene (compound 5) and 1-[(1R)-1-(Dicyclohexylphosphino)ethyl]-2-(diphenylphosphino)ferrocene (compound 6). Among the columns used, the Lux i-Cellulose-5 was the most effective. In capillary electrokinetic chromatography, a phosphate buffer of 25 mM concentration and pH equal to 2.5 was chosen as background electrolyte, leading to cationic ferrocene derivatives. The addition of neutral cyclodextrins was undertaken first and native β- or γ-cyclodextrins were found to resolve the enantiomers of two derivatives. Then, 15 mM of anionic cyclodextrins were added to the background electrolyte. The use of SBE-β-CD, S-β-CD or S-γ-CD have allowed the separation of the enantiomers for most of the ferrocene derivatives studied with high resolution values in short migration time. For instance, for 1-(R)-2-(Diphenylphosphino)ethyldi-tert-butylphosphine ferrocene (compound 2), the migration times were less than 2 minutes and the resolution value was equal to 3.52 in short-end mode with 15 mM S-β-CD, at 25 kV and 25°C. Finally, a dual cyclodextrins system was tested using 15 mM of S-β-CD plus 15 mM HP-γ-CD in the phosphate buffer. This system allowed the improved separation of two ferrocene derivatives with an unusual resolution value equal to 41.5 in long-end mode. Overall, CEKC showed better enantioseparating power of the six chiral ferrocenes studied than liquid chromatography.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...