Abstract:
Mechanical insufflation-exsufflation (MI-E) has been used to supplement the ability to cough and expel pulmonary secretions in patients with neuromuscular disease who have a reduced ability to cough. The manufacturer's guidelines for MI-E recommend a setting of inspiratory pressure of +40 cmH2O and expiratory pressure of -40 cmH2O. However, patients with small stature and restricted ventilatory impairment are prone to pneumothorax, so the manufacturer's recommendations are not used as is, and should be adjusted for the physical and pulmonary characteristics of each patient. Here, we report a case in which MI-E was used for an amyotrophic lateral sclerosis (ALS) patient with short height, low BMI, and restricted lung capacity at inspiratory and expiratory pressures lower than the manufacturer's recommendations. In adjusting MI-E pressure, physical observations such as chest auscultation, visual chest dilation, and observation of secretion movement toward the tracheal tube were performed to avoid unnecessary pressure. As a result, the pressure level set was lower than the manufacturer's recommendation (25 cmH2O) but sufficient to improve atelectasis and no pneumothorax occurred. The method we practiced in this study is feasible in any clinical setting. We also believe that MI-E, when performed in conjunction with treatment response observation, can be expected to improve at lower pressures than generally recommended, thereby reducing the risk of lung injury and providing safer treatment.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Pulmonary Cycle: Exhalation