Related Experiment Video
Updated: Sep 5, 2025

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective,
Antonius Schneider1, Benjamin Brunn1, Alexander Hapfelmeier1,2
1TUM School of Medicine, Institute of General Practice and Health Services Research, Technical University of Munich, Munich, Germany.
Background:
Fractional exhaled nitric oxide (FeNO) is promising for diagnosing asthma and could replace bronchial provocation (BP). To date, cut-off values have been derived by post hoc analysis only. The aim was to validate the diagnostic accuracy for predefined FeNO cut-off values and the predictive value for responsiveness to inhaled corticosteroids (ICS).
Methods:
We conducted a prospective, diagnostic, multicentre study with patients attending three private practices of pneumologists in Upper Bavaria, Germany, from July 3, 2020 to Jan 21, 2022. Index test was FENO measurement. Reference standard was Tiffeneau ratio (FEV1/VC) or airway resistance as assessed by whole body plethysmography, with additional BP or bronchodilation test. Follow-up was performed after 12 weeks. Analyses of Receiver Operating Characteristics curves were conducted to determine the diagnostic accuracy and predictive value of FeNO.
Findings:
308 patients with complete follow-up were recruited, 186 (60·4%) were female, average age was 44·7 years, 161 (52·3%) had asthma. Regarding diagnostic accuracy, the area under the curve (AUC) was 0·718 (95% CI 0·661-0·775; p < 0·001). Sensitivity at FeNO >50 ppb was 0·24 (95% CI 0·18-0·32), specificity 0·99 (0·95-1·0), positive predictive value (PPV) 0·95 (0·84-0·99), negative predictive value (NPV) 0·54 (0·48-0·60). In 66 patients with ´wheezing´ and ´allergic rhinitis´, the sensitivity at FeNO >33 ppb was 0·49 (0·34-0·64), specificity 0·88 (0·64-0·99), PPV 0·92 (0·75-0·99), NPV 0·38 (0·23-0·54). In 68 patients with ICS medication, responsiveness was predicted at the cut-off >43 ppb, with a sensitivity of 0·55 (95%CI 0·36-0·74), specificity 0·82 (0·66-0·92), PPV 0·70 (0·47-0·87), NPV 0·71 (0·56-0·84).
Interpretation:
FeNO measurement allows a valid ruling-in of an asthma diagnosis, whereas ruling-out of asthma is not possible. Enhanced probability of ICS responsiveness is also given with increased FeNO values.
Funding:
Circassia Germany gave 25% discount on the purchase of three NIOX VERO devices.
Related Concept Videos
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Antiasthma Drugs: β2-Adrenoceptor Agonists
One class of bronchodilators includes β2-adrenoceptor agonists. These agents target the β2-adrenoceptors located on bronchial smooth muscle cells. By stimulating these receptors, β2-agonists induce...
Sensitivity, Specificity, and Predicted Value