Toru Adachi1, Tetsuya Asakawa2, Yasuteru Yamauchi3
1Department of Cardiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan.
Background:
Specific pacing methods to unmask the existence of the dual atrioventricular (AV) nodal pathway in patients with dual AV nodal non-reentrant tachycardia remain to be established.
Objective:
This study aimed to determine the electrophysiological characteristics of dual AV nodal non-reentrant tachycardia by its responses to specific pacing methods.
Methods:
Five patients diagnosed as having dual AV nodal non-reentrant tachycardia were retrospectively investigated.
Results:
Atrial pacing could not induce the clinical tachycardia as continuous double firing in any of the 5 patients, but did induce sudden prolongation of the A-H interval as the linking phenomenon in 1 patient. A single atrial extrastimulation after sinus excitations was performed without interruption of double firing in 1 patient, and it induced the double ventricular response phenomenon within the limited range of the extrastimulus intervals. The pacing method of AV simultaneous basic pacing preceding atrial programmed extrastimulation did not allow interruptions of double firing during the basic drive trains and induced the double ventricular response phenomenon within the limited range of the extrastimulus intervals in all 5 patients, even in 1 patient without inducibility of the clinical tachycardia in the catheterization laboratory. The double ventricular response phenomenon within the limited range of the extrastimulus intervals may be based on the existence of the dual AV nodal pathway with concealed retrograde penetration.
Conclusion:
The AV simultaneous basic pacing preceding atrial programmed extrastimulation method consistently and reproducibly unmasked the existence of the dual AV nodal pathway as the double ventricular response phenomenon in patients with dual AV nodal non-reentrant tachycardia.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias