Related Experiment Video
Updated: Sep 5, 2025

Isolation of Quartz Grains for Optically Stimulated Luminescence OSL Dating of Quaternary Sediments for Paleoenvironmental Research
Published on: August 2, 2021
Thermoluminescence (TL), kinetic parameters and dosimetric features of Pakistani limestone
M Masood Mahmood1, M Basim Kakakhel2, M Wazir-Ud-Din2
1Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, 45650, Pakistan; Heath Physics Division, PINSTECH, Nilore, Islamabad, Pakistan.
Abstract:
Thermoluminescence (TL), kinetic parameters and dosimetric features of Pakistani limestone (CaCO3) is reported in this study. Both compositional and structural analyses reveal that the material has a crystalline nature with rhombohedral structure and non-uniform crystallite size having major content of CaCO3. A powdered limestone sample of 30 mg is found to be the optimized weight for TL and other dosimetric studies. After irradiating the samples with a test dose of 100 Gy using a β source three composite glow peaks termed as P1, P2 and P3 are visible at 100, 230 and 330 °C respectively using a linear heating rate of 1 °C/s during the TL readout. The Coefficient of Variation (COV) is found to be about 4%. Kinetic parameters (i.e., frequency factor (f), activation energy (E), and the kinetic order (b)) are estimated using both first and second Order of kinetics using an in-house Computerized Glow Curve Deconvolution (GCD) software. The figure-of-merit (FOM) is found to be 2.12%. The distribution of continuum traps with activation energy in the range of 0.77-2.59 eV is observed in the kinetic parameter analysis of the glow peaks of the sample. The TL response in the dose range of 1-5 Gy (not reported previously) and linearity in the dose response in the dose range of 1-10 Gy is observed in samples of Pakistani limestone. The Minimum Detectable Dose (MDD) is 1.01 Gy clearly resembling the experimentally linear fitted results. After a fading study for a period of thirty days, only the first peak i.e., P1 majorly fades while no major change is observed in the amplitude of peaks P2 and P3. In addition, P1 is the main contributor fading by 92% within the first 24 h of irradiation while P2 fades by 30 %. However, P3 shows stability with a very minor fading of 0.05% within 24 h of irradiation. This study concludes that Pakistani limestone can be further assessed as a potential radiation dosimeter for various applications.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
06:06A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016