Related Experiment Video
Updated: Sep 4, 2025

Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation
Published on: July 15, 2015
Long-term Transplant Function After Thrombolytic Treatment Ex Vivo of Donated Kidneys Retrieved 4 to 5 H After
Michael Olausson1,2, Deepti Antony2, Martin Johansson3
1Department of Transplantation, Sahlgrenska Academy, Gothenburg University and the Sahlgrenska Transplant Institute at Sahlgrenska University Hospital, Gothenburg, Sweden.
Background:
Using a novel thrombolytic technique, we present long-term transplant function, measured by creatinine and iohexol clearance, after utilizing kidneys from porcine donors with uncontrolled donation after circulatory deaths, with 4.5-5 h of warm ischemia.
Methods:
Pigs in the study group were subjected to simulated circulatory death. After 2 h, ice slush was inserted into the abdomen and 4.5 h after death, the kidneys were retrieved. Lys-plasminogen, antithrombin-III, and alteplase were injected through the renal arteries on the back table. Subsequent ex vivo perfusion was continued for 3 h at 15°C, followed by 3 h with red blood cells at 32°C, and then transplanted into pigs as an autologous graft as only renal support. Living-donor recipient pigs that did not receive ex vivo perfusion, and unilateral nephrectomized pigs served as the controls.
Results:
Pigs in the study group (n = 13), surviving 10 d or more were included, of which 7 survived for 3 mo. Four animals in the living-donor group (n = 6) and all 5 nephrectomized animals survived for 3 mo. Creatinine levels in the plasma and urine, neutrophil gelatinase-associated lipocalin levels, Kidney Injury Marker-1 expression, and iohexol clearance at 3 mo did not differ significantly between the study and living-donor groups. Histology and transmission electron microscopy after 3 mo showed negligible fibrosis and no other damage.
Conclusions:
The present method salvages kidneys from extended unontrolled donation after circulatory death using thrombolytic treatment while preserving histology and enabling transplantation after ex vivo reconditioning, with clinically acceptable late function after 3 mo, as measured by creatinine and iohexol clearance.