Related Experiment Video
Updated: Sep 4, 2025

Assessment of Neuromuscular Function Using Percutaneous Electrical Nerve Stimulation
Published on: September 13, 2015
Mechanical Effects of a Specific Neurodynamic Mobilization of the Superficial Fibular Nerve: A Cadaveric Study
Felix-Antoine Lavoie1, Marc-Olivier St-Pierre1, Jean-Philippe Paquin2
1Department of Human Kinetics, Université du Québec à Trois-Rivières, Canada.
Context:
A specific neurodynamic mobilization for the superficial fibular nerve (SFN) has been suggested in the reference literature for manual therapists to evaluate nerve mechanosensitivity in patients. However, no authors of biomechanical studies have examined the ability of this technique to produce nerve strain. Therefore, the mechanical specificity of this technique is not yet established.
Objectives:
To test whether this examination and treatment technique produced nerve strain in the fresh frozen cadaver and the contribution of each motion to total longitudinal strain.
Design:
Controlled laboratory study.
Setting:
Laboratory.
Main Outcome Measure(S):
A differential variable reluctance transducer was inserted in 10 SFNs from 6 fresh cadavers to measure strain during the mobilization. A specific sequence of plantar flexion, ankle inversion, straight-leg raise position, and 30° of hip adduction was applied to the lower limb. The mobilization was repeated at 0°, 30°, 60°, and 90° of the straight-leg raise position to measure the effect of hip-flexion position.
Results:
Compared with a resting position, this neurodynamic mobilization produced a significant amount of strain in the SFN (7.93% ± 0.51%, P < .001). Plantar flexion (59.34% ± 25.82%) and ankle inversion (32.80% ± 21.41%) accounted for the biggest proportions of total strain during the mobilization. No difference was noted among different hip-flexion positions. Hip adduction did not significantly contribute to final strain (0.39% ± 10.42%, P > .05), although high variability among limbs existed.
Conclusions:
Ankle motion should be considered the most important factor during neurodynamic assessment of the SFN for distal entrapment. These results suggest that this technique produces sufficient strain in the SFN and could therefore be evaluated in vivo for correlation with mechanosensitivity.