Related Experiment Video
Updated: Sep 4, 2025

Measuring Fluxes of Mineral Nutrients and Toxicants in Plants with Radioactive Tracers
Published on: August 22, 2014
Activity standardization of two enriched 40K solutions for the determination of decay scheme parameters and the
Karsten Kossert1, Yuri Amelin2, Dirk Arnold1
1Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116, Braunschweig, Germany.
Abstract:
In this paper we describe experiments on two enriched 40K solutions to accurately determine decay data. The first solution was measured in 2004/2005 by means of a gamma-ray spectrometer with low background and a liquid scintillation (LS) counter to apply the CIEMAT/NIST efficiency tracing method. A combination of results yields an emission probability of the 1461 keV gamma-rays of Pγ = 0.1030(11) which is lower than current results of data evaluations. The activity concentration of the second solution was also determined by means of LS counting, but here, the CIEMAT/NIST efficiency tracing method as well as the TDCR method were applied. Again, the result was combined with that of independent gamma-ray spectrometry and the gamma-ray emission probability was found to be Pγ = 0.1029(9) in good agreement with the result obtained from the first solution. A combination of both experiments yields Pγ = 0.1029(9). The spectra of a TriCarb LS counter were carefully analyzed and a beta minus emission probability [Formula: see text] = 0.8954(14) was determined. The new results for Pγ and [Formula: see text] indicate that the overall probability of the decay via EC in recent data evaluations is overestimated. The LS counting efficiencies were computed with a stochastic model and up-to-date calculations of the beta spectrum and fractional EC probabilities were used. The final activity result of the second solution is combined with the outcome of a comprehensive isotopic analysis to determine the half-life of 40K which is found to be 1.2536(27) ·109 years. All above-stated uncertainties are standard uncertainties (k = 1).
Related Concept Videos
Radioactive Decay and Radiometric Dating
Nuclear Stability
To hold positively charged protons together...
Flame Photometry: Lab
Isotopes and Radioisotopes
An isotope containing...
Radioactivity and Nuclear Equations
A nuclide of an element has a specific number of protons and...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...