A side-by-side comparison of the performance and time-and-motion data of VITEK MS
Marta Bardelli1, Michela Padovani1, Simona Fiorentini1
1Section of Microbiology, Department of Molecular and Translational Medicine, University of Brescia, UOC Microbiology and Virology ASST Spedali Civili Di Brescia, Brescia, Italy.
Abstract:
Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry systems are designed for rapid and reliable microbial identification. VITEK MS PRIME is the bioMérieux's new generation instrument equipped with a continuous load-and-go sample loading system, urgent slide prioritization for critical patient samples and new internal components for faster identification. The aim of this study was to assess the performance of VITEK MS PRIME and to compare it to that of the VITEK MS system. In addition, at two sites, we performed a time-and-motion study to evaluate the efficiency of sample analysis from colony picking to slide removal from the instrument. We analyzed by VITEK MS and VITEK MS PRIME a total of 1413 isolates (1320 bacterial and 76 yeast) deriving from routine diagnostic samples that came into four laboratories in Canada, France, Italy, and Spain. VITEK MS PRIME and VITEK MS were concordant to the species and genus level for 1354/1413 (95.8%) and to the species level for 1341/1413 (94.9%). The identification and concordance rates in individual centers were largely homogenous. Overall, VITEK MS PRIME identified 1370/1413 (97.0%) of isolates compared to 1367/1413 (96.7%) identified by VITEK MS. Identification rates were consistently high for all microorganism categories. A time-and-motion study showed that the use of VITEK MS PRIME was associated with significant time saving. VITEK MS PRIME performs as well as VITEK MS and reduces the time necessary for pathogen identification. To fully optimize the laboratory process and obtain maximum efficiency, VITEK MS PRIME must be integrated into the laboratory workflow.
Related Concept Videos
Velocity and Position by Graphical Method
Average and Instantaneous Velocity Vectors
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Voltammetric Techniques: Linear-Scan (E vs Time)
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis - Acceleration