Related Experiment Video
Updated: Sep 4, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Passive leg raising-induced changes in pulse pressure variation to assess fluid responsiveness in mechanically
Jihad Mallat1, Marc-Olivier Fischer2, Maxime Granier3
1Department of Critical Care Medicine, Arras Hospital, Arras, France; Critical Care Institute, Cleveland Clinic Abu Dhabi, Abu Dhabi, United Arab Emirates; Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, USA; Normandy University, UNICAEN, Ecole Doctorale NBISE 497, Caen, France.
Background:
Passive leg raising-induced changes in cardiac index can be used to predict fluid responsiveness. We investigated whether passive leg raising-induced changes in pulse pressure variation (ΔPPVPLR) can also predict fluid responsiveness in mechanically ventilated patients.
Methods:
In this multicentre prospective observational study, we included 270 critically ill patients on mechanical ventilation in whom volume expansion was indicated because of acute circulatory failure. We did not include patients with cardiac arrythmias. Cardiac index and PPV were measured before/during a passive leg raising test and before/after volume expansion. A volume expansion-induced increase in cardiac index of >15% defined fluid responsiveness. To investigate whether ΔPPVPLR can predict fluid responsiveness, we determined areas under the receiver operating characteristic curves (AUROCs) and grey zones for relative and absolute ΔPPVPLR.
Results:
Of the 270 patients, 238 (88%) were on controlled mechanical ventilation with no spontaneous breathing activity and 32 (12%) were on pressure support ventilation. The median tidal volume was 7.1 (inter-quartile range [IQR], 6.6-7.6) ml kg-1 ideal body weight. One hundred sixty-four patients (61%) were fluid responders. Relative and absolute ΔPPVPLR predicted fluid responsiveness with an AUROC of 0.92 (95% confidence interval [95% CI], 0.88-0.95; P<0.001) each. The grey zone for relative and absolute ΔPPVPLR included 4.8% and 22.6% of patients, respectively. These results were not affected by ventilatory mode and baseline characteristics (type of shock, centre, vasoactive treatment).
Conclusions:
Passive leg raising-induced changes in pulse pressure variation accurately predict fluid responsiveness with a small grey zone in critically ill patients on mechanical ventilation.
Clinical Trial Registration:
NCT03225378.
Related Concept Videos
Measurement of Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulse
The pulse serves as a clinical...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...