Related Experiment Video
Updated: Sep 4, 2025

Generation of Murine Cardiac Pacemaker Cell Aggregates Based on ES-Cell-Programming in Combination with Myh6-Promoter-Selection
Published on: February 17, 2015
Premature Ventricular Contractions Are Presaged by a Mechanically Abnormal Sinus Beat
Christina Alhede1, Satoshi Higuchi1, Alexios Hadjis1
1Section of Electrophysiology, University of California-San Francisco, San Francisco, California, USA.
Background:
Frequent premature ventricular contractions (PVCs) can lead to cardiomyopathy; it is unclear if there are abnormal myocardial mechanics operative in the PVC and non-PVC beats.
Objectives:
The aim of this study was to investigate regional and global myocardial mechanics, including dyssynchrony, in patients with frequent PVCs.
Methods:
Fifty-six consecutive patients referred for PVC ablation were prospectively studied. During sinus rhythm (SR) and PVC beats, left ventricular (LV) global longitudinal strain (GLS), LV dyssynchrony (measured as the SD of time to peak GLS), and dyssynergy (measured as maximum regional strain minus minimum regional strain at aortic valve closure) were quantified using 2-dimensional strain echocardiography. GLS, dyssynchrony, and dyssynergy were compared in remote SR, pre-PVC SR, PVC, and post-PVC SR beats.
Results:
In SR beats remote from the PVC, GLS was -17.3% ± 4%, dyssynchrony was 49 ± 14 ms, and dyssynergy was 22% ± 9%. Myocardial mechanics were significantly abnormal during PVCs compared with remote SR beats (GLS -7.7% ± 3% [P < 0.001], dyssynchrony 115 ± 37 milliseconds [P < 0.001], and dyssynergy 26% ± 10% [P < 0.001]). There were significant mechanical abnormalities in the SR beat preceding the PVC, which demonstrated significantly lower LV strain (pre-PVC SR, -13% ± 4%; P < 0.001) and more dyssynchrony (pre-PVC SR, 63 ± 19 milliseconds; P < 0.001) compared with remote SR beats. Dyssynergy was significantly higher for pre-PVC SR and PVC beats compared with remote SR (pre-PVC SR, 25% ± 8% [P < 0.001]; PVC, 26% ± 10% [P < 0.001]).
Conclusions:
In patients with frequent PVCs, the SR beat preceding the PVC demonstrates significant mechanical abnormalities. This finding suggests that perturbations in cellular physiological processes such as excitation-contraction coupling may underlie the generation of frequent PVCs.
More Related Videos
Related Concept Videos
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Dysrhythmias II: Classification of Tachyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias