Silicone Breast Implant Rupture From Pectoralis Muscle Contraction Causing IgA Nephropathy: A Case Report
Mahno Noor Ezmas1, Abdullah Norlia2, Aziz Suraya3
1Department of Surgery, Kulliyyah of Medicine, International Islamic University Malaysia, Kuantan, Malaysia.
Abstract:
A 34-year-old woman who was diagnosed with a left breast carcinoma underwent breast conserving surgery and axillary dissection. This was followed with adjuvant breast irradiation and endocrine therapy. She had a local recurrence in the breast 7 years later. She underwent a left nipple sparing mastectomy and submuscular implant reconstruction. The silicone implant ruptured during an episode of strong pectoralis muscle contraction, 5 years postimplantation. MRI confirmed the rupture to be intracapsular and extracapsular. She declined implant replacement. She presented with painless hematuria 2.5 years after the rupture. A renal biopsy confirmed IgA nephropathy.