Abnormal flow conduction through pulmonary arteries is associated with right ventricular volume and function in
Daniel McLennan1, Michal Schäfer2, Alex J Barker3,4
1Division of Cardiology, Department of Pediatrics, Heart Institute, Children's Hospital Colorado, University of Colorado Denver | Anschutz Medical Campus, 13123 E 16th Ave, Aurora, CO, 80045-2560, USA.
Objectives:
Flow through the proximal pulmonary arteries (PAs) of patients with repaired Tetralogy of Fallot (TOF) is known to be highly disordered and associated with significant regurgitation. The purpose of this study was to evaluate 4D-Flow MRI-derived viscous energy loss [Formula: see text])-as a result of non-efficient flow propagation, and relate this parameter to standard right ventricular (RV) size and function markers in patients with repaired TOF.
Methods:
Thirty-five patients with TOF and 14 controls underwent comprehensive 4D-Flow MRI evaluation for qualitative flow analysis and to calculate [Formula: see text] in the main and right pulmonary arteries. Sampled [Formula: see text] indices were correlated with the MRI-derived RV size and functional indices.
Results:
All patients with TOF exhibited abnormal, supra-physiologic helical/vortical formations in the PAs. Patients with TOF had significantly increased peak systolic [Formula: see text] (8.0 vs 0.5 mW, p < 0.001), time-averaged [Formula: see text] (2.5 vs. 0.2 mW, p < 0.001), and peak systolic [Formula: see text] indexed to stroke volume (0.082 vs. 0.012 mW/mL, p < 0.001). [Formula: see text] indexed to stroke volume correlated with the RV end-diastolic volume (R = 0.68, p < 0.001), end-systolic volume (R = 0.62, p < 0.001), ejection fraction (R = -0.45, p = 0.002), and cardiac index (R = 0.45, p = 0.002). The mean estimated energy loss due to [Formula: see text] with regard to input RV mechanical power was 4.7%.
Conclusion:
This study demonstrates that patients with repaired TOF have highly abnormal flow conduction through the PAs which result into extensive viscous energy loss. This significant flow-mediated energy loss is associated with the RV volume and function, and might represent considerable loss of mechanical power generated by each cardiac cycle. Future studies are required to assess whether the abnormal flow conduction adds to the RV afterload and remodeling.
Key Points:
• Abnormal flow patterns through proximal pulmonary arteries in patients with TOF are associated with excessive viscous energy loss. • Inefficient flow conduction is associated with the RV dilation and reduced function and might contribute to the RV adaptive remodeling.
More Related Videos
07:11Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
Related Concept Videos
Mitral Stenosis I: Introduction
Aortic Regurgitation I: Introduction
Mitral Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management