Related Experiment Video
Updated: Sep 4, 2025

Spatial Separation of Molecular Conformers and Clusters
Published on: January 9, 2014
The separation regularity of the three-phase solvent system of counter-current chromatography based on polarity
Jun-Xian Jing1, Jules Muhire1, Xiao Sun1
1CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory of Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Lanzhou 730000, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
The three-phase solvent system of counter-current chromatography can separate compounds with a wide range of polarity, but there is no study of its separation regularity. Therefore, in this work, the separation regularity of the three-phase solvent system was initially investigated from the perspective of solvent polarities and compound polarities. The standard compounds covering a wide polarity range were selected, and three-phase solvent systems, n-hexane/methyl acetate/acetonitrile/water, and n-hexane/methyl tert-butyl ether/acetonitrile/water were used for modeling. The results showed that in the three-phase solvent system, the partition coefficient for the middle and lower phases (lgKM/L) increased with increasing logP values in three intervals logP < 0, 0 < logP < 4, and logP > 4. In addition, the partition coefficient for the upper and middle phases (lgKU/M) between the upper and middle phases of the small polarity compounds increases with increasing logP values. LogP vs lgKM/L of 7 solvent systems were employed for the smoothing spline fit through a predictive model design of the curve fitting toolbox in MATLAB software, and good results were achieved. LogP versus lgKM/L for n-hexane/methyl tert-butyl ether/acetonitrile/water solvent systems were used for the second-order power fit, and satisfactory results were obtained. The relationship between polarity parameters and separation case parameters was explored using a heat map approach. The separation regularity of the three-phase solvent system was preliminarily investigated. This regularity study gives hope of assistance to the chemists studying three-phase solvents and counter-current chromatography.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...

