Related Experiment Video
Updated: Sep 4, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Radiomics in photon-counting dedicated breast CT: potential of texture analysis for breast density classification
Anna Landsmann1, Carlotta Ruppert2, Jann Wieler3
1Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland. anna.landsmann@usz.ch.
Background:
We investigated whether features derived from texture analysis (TA) can distinguish breast density (BD) in spiral photon-counting breast computed tomography (PC-BCT).
Methods:
In this retrospective single-centre study, we analysed 10,000 images from 400 PC-BCT examinations of 200 patients. Images were categorised into four-level density scale (a-d) using Breast Imaging Reporting and Data System (BI-RADS)-like criteria. After manual definition of representative regions of interest, 19 texture features (TFs) were calculated to analyse the voxel grey-level distribution in the included image area. ANOVA, cluster analysis, and multinomial logistic regression statistics were used. A human readout then was performed on a subset of 60 images to evaluate the reliability of the proposed feature set.
Results:
Of the 19 TFs, 4 first-order features and 7 second-order features showed significant correlation with BD and were selected for further analysis. Multinomial logistic regression revealed an overall accuracy of 80% for BD assessment. The majority of TFs systematically increased or decreased with BD. Skewness (rho -0.81), as a first-order feature, and grey-level nonuniformity (GLN, -0.59), as a second-order feature, showed the strongest correlation with BD, independently of other TFs. Mean skewness and GLN decreased linearly from density a to d. Run-length nonuniformity (RLN), as a second-order feature, showed moderate correlation with BD, but resulted in redundant being correlated with GLN. All other TFs showed only weak correlation with BD (range -0.49 to 0.49, p < 0.001) and were neglected.
Conclusion:
TA of PC-BCT images might be a useful approach to assess BD and may serve as an observer-independent tool.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging